Lumens to Lux Calculator

Convert lumens to estimated lux using a known lit area, cone beam, or bare bulb spread.

Advanced options
Calculating...
Estimated light on the surfaceHigher lux means more light hits each square meter of the surface.
Same estimate in foot-candlesThis is the same light level shown in a different unit.
Area used in the lux mathA larger area spreads the same lumens thinner, so lux goes down.
Lumens used after light reaching percentIf the percent is less than 100, the calculator estimates less light reaching the surface.
Assumption used
Did we solve your problem today?


How to use our Lumens to Lux Calculator

  1. Choose How the light spreads: Known lit area for a measured surface, Cone-shaped beam for a spotlight, or Bare bulb all directions for an open bulb.
  2. Enter Light output (lumens), then enter only the measurement needed for that method: Lit area (square feet), Distance to surface (feet), and Full beam angle (degrees) when shown.
  3. Open Advanced options if needed, then set Light reaching the surface (percent), Target to compare (lux, optional), and Number format.
  4. Select Calculate and read Estimated light on the surface first, then check Area used in the lux math and Assumption used to make sure the method matches your real setup.
  5. Sanity-check the answer: if the area is huge, the lux should drop; if the distance doubles for a beam or bare bulb, the lux should usually be much lower.
Example inputs for Lumens to Lux Calculator
Example inputs for Lumens to Lux Calculator

Definitions

Lumens: Total visible light output from a source. More lumens means more total light, but not always more lux on your surface.

Lux: Light level on a surface. One lux is one lumen spread over one square meter [1].

Foot-candles: A US light-level unit equal to lumens per square foot. The calculator also shows Same estimate in foot-candles.

Effective lit area: The square-meter area used in the lux math after the selected spread method is converted.

Full beam angle: The full width of a cone-shaped beam, measured in degrees. It is not the half angle from the center line to one edge.

Light reaching the surface (percent): The percent of the rated lumens assumed to reach the target surface after shade, fixture loss, spill, or blockage.


Example lux by spread methodSame 800 lm source at 10 ft gives very different illuminance depending on how the light spreads. Use this as a sanity check: tighter spread means higher lux on the surface.Example lux by spread methodSame 800 lm source at 10 ft gives very different illuminance depending on how the light spreadsKnown area 100 ft^286.1 lxCone beam 60 deg82.2 lxBare bulb sphere6.9 lxSpread assumption
Example lux by spread method
Use this as a sanity check: tighter spread means higher lux on the surface.

Common mistakes and quick fixes

Mistake: Picking Known lit area in How the light spreads for a narrow spotlight.
Fix: Use Cone-shaped beam if the light has a Full beam angle (degrees), then check Assumption used.

Mistake: Entering watts instead of lumens in Light output (lumens).
Fix: Use the lumen rating from the bulb, fixture, projector, or lamp label.

Mistake: Using the whole room size for Lit area (square feet) when only a desk or wall is lit.
Fix: Enter the surface that actually receives the light, then compare it with Area used in the lux math.

Mistake: Measuring Distance to surface (feet) from the ceiling or floor instead of from the light source.
Fix: Measure from the bulb, LED, lens, or fixture opening to the surface you care about.

Mistake: Entering a half angle in Full beam angle (degrees).
Fix: Enter the full listed beam angle, such as 60 degrees, not 30 degrees.

Mistake: Treating a negative Amount above or below your target as an error.
Fix: A negative value means Estimated light on the surface is below Target to compare (lux, optional).


Limitations & Key Assumptions / Boundary Conditions

  • The Known lit area method assumes the entered Lit area (square feet) is the area that actually receives the light.
  • The Cone-shaped beam method assumes an evenly filled circular beam on a surface perpendicular to the beam.
  • The Bare bulb all directions method assumes an ideal point source that sends light evenly in every direction.
  • Real fixtures can have reflectors, lenses, shades, hot spots, spill light, and room reflections, so measured lux can differ from the estimate.
  • Light reaching the surface (percent) is a user estimate. If that percent is wrong, Effective lumens and Estimated light on the surface will be wrong.
  • The calculator estimates average lux over the computed area, not the brightest point or the darkest point.
  • Target to compare (lux, optional) is only your chosen target. It is not a built-in lighting code or task recommendation.

Methodology

Core idea

The calculator first reduces the entered Light output (lumens) by Light reaching the surface (percent). It then spreads those effective lumens over the area that matches How the light spreads. Lux is lumens per square meter, so the main result is effective lumens divided by effective area.

effective_lumens = lumens * light_reaching_percent / 100

Known lit area

For Known lit area, the calculator converts Lit area (square feet) to square meters, then divides effective lumens by that area.

area_m2 = lit_area_ft2 * 0.09290304

lux = effective_lumens / area_m2

Cone-shaped beam

For Cone-shaped beam, the calculator converts Distance to surface (feet) to meters, uses Full beam angle (degrees) to find the beam radius, and treats the footprint as a circle.

distance_m = distance_ft * 0.3048

radius_m = distance_m * tan(beam_angle_deg * pi / 360)

area_m2 = pi * radius_m^2

lux = effective_lumens / area_m2

Bare bulb all directions

For Bare bulb all directions, the calculator treats the light as if it is spread over the surface area of a sphere at the entered distance.

distance_m = distance_ft * 0.3048

area_m2 = 4 * pi * distance_m^2

lux = effective_lumens / area_m2

Extra outputs

Foot-candles are calculated from the same lux result. The target comparison stays signed so a negative value clearly means the estimate is below your target.

foot_candles = lux / 10.76391

target_gap_lux = lux - target_lux

Mini example

For 1000 lumens over 100 square feet with 100 percent reaching the surface, the effective lumens are 1000 and the converted area is 9.290304 m^2.

lux = 1000 / 9.290304 = 107.64 lx

foot_candles = 107.64 / 10.76391 = 10.00 fc